Atributos
Peso |
0.94 lb
|
---|---|
Break Quantity |
1
|
Paquete Opcional/Cantidad por Caja |
1
|
Material |
Latón
|
DE Máximo |
|
Rosca |
NPTF
|
Tamaño de Cuerpo |
|
Rango de Temperatura |
6" grooved manifold with six 2" female NT ports, one 1" NPT port (left or right version)°F (Not pressure retaining, open flow only°C)
|
Medida de Rosca |
|
Longitud |
|
Hex |
|
Valor de Presión |
Detalles
Compatibilidad e Intercambio de Datos
- Foster 3, 4, 5 and 6 Series
- Parker 30 - Series Automatic Interchange
- Hansen 3000, 4000, 5000 and 6000
Construcción
- Machined components are manufactured using solid bar stock.
- Stainless steel balls, retaining rings and springs maximize corrosion resistance and extend service life.
- Nitrile (Nitrile Rubber) seals are standard
- Steel componentry is plated using ROHS Compliant Trivalent Chrome.
- Steel prong valve
Como funciona
- To disconnect, begin by holding the hose on the nipple side with three of your fingers, leaving your thumb and index finger free.
- Grab the sleeve with your thumb and index finger and begin to pull the sleeve towards the palm of your hand.
- After pulling the sleeve, the nipple will move out of the coupler slightly. Continue to hold the hose and coupler sleeve until all air is fully exhausted.
- After the line is fully exhausted, you are able to safely separate the nipple from the coupler.
Notas de Seguridad
It is important to be safe when installing quick disconnect couplings into a pneumatic circuit. Never install a pneumatic coupling directly into an air tool, use a piece of hose that is at least 18" long, between the tool and the coupling, to prevent damage to the coupling. To protect the operator, safety devices, such as a safety check valve and safety cable should be installed in case there is a hose or coupling failure.
Especificaciones
Rated pressure for connected Brass Coupler & Brass Plug: 500 PSI (35 bar) Maximum Working and 10,000 PSI (670 bar) Burst
WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.